Extended System-Level Command Functions
118 Class Series 2 Programmer’s Manual
STX KtU Read Unique Serial Number from RFID Tag
(Direct Mode – HF [13.56 MHz] ISO15693 Tag Interface)
This command instructs the RFID device to read the unique serial number data from the
tag and then place that data into a replaceable field. It is expected that the tag
transponder will be within the read / write distance of the RFID programming device;
otherwise, “Void” will be printed in the text or bar code label field(s).
This is a sixteen character alphanumeric value; the replaceable field must have an
adequate length.
Syntax:
<
STX>KtU
a
bc
c
<
CR
>
Where:
a
-
The number of retry attempts, 0-9.
b
-
Reserved. Should be 0.
cc
-
Field number in which to place the data (must be 01,
02, 03, etc.) matching the order of Label Formatting
command, U.
A 00 value will send the ID to the host with no printing.