98 H-Class
A. Turn OFF the Power Switch and unplug the power cord from the AC Receptacle.
B. Raise the Cover then remove the Door and tearbar. Unlock the Printhead Latch and
raise the Printhead Assembly.
C. Remove media and ribbon.
D. Using a Cotton Swab (or lint-free cloth) dampened with isopropyl alcohol, wipe the
Platen and the Assist Roller clean. Manually rotate the rollers as necessary, wiping,
rotating, and repeating until the surfaces of each are clean.
5.5.6 Cleaning the Ribbon Path Components (Thermal Transfer equipped)
Smooth ribbon flow can become impeded if the components are dirty. Clean them as follows:
A. Turn OFF the Power Switch and unplug the power cord from the AC Receptacle. Raise
the Cover then remove media and ribbon.
B. Using a Cotton Swab dampened with alcohol, wipe the Ribbon Idlers clean.