Printer Options (continued)
Menu Item Details
MIN READABLE HEIGHT
Ensures bar code integrity by setting a minimum
distance for identical decodes, where:
DISABLED Uses REDUNDANCY LEVEL to ensure bar code
integrity.
1/16 – ½ in.
(1.5 – 12.5 mm)
Sets the read height (e.g., a setting of ¼ requires .25
inches of the bar code height be 100% readable).
This distance should not exceed 50% of the
measured bar code height.
REDUNDANCY LEVEL
Ensures bar code integrity by specifying a consecutive
number of identical decodes, where:
(1X – 6X)
3X
Sets the read count (e.g., a 3X setting requires three
identical decodes to pass).
High redundancy rates and fast print speeds can
cause erroneous failures when scanning small or
multiple bar codes.
AUTO
Uses MIN READABLE HEIGHT to ensure bar code
integrity.
IGNORE NO DATA
Allows an override of the verification function, where:
DISABLED
Checks for correct bar code data in the bar code(s).
ENABLED
Ignores the data present in the bar code(s).
SET DEFAULTS
Allows the scanner default values to be restored,
where:
YES
Restores the default settings.
NO
Exits the menu item without changing the current
settings.