Datamax-oneil H-Class Operator’s Manual Manuel d'utilisateur Page 47

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 180
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 46
H-Class 37
Media Settings (continued)
Menu Item Details
PRINTHEAD CLEANING
Controls printhead cleaning alerts and functions,
where:
CLEAN HEAD SCHEDULE
0 – 200 in.(* 1000)
000
Specifies the inch (or centimeter) count (multiplied by
one thousand) at which to clean the printhead. If this
count is exceeded three times, a Head Cleaning Fault
will occur.
Zero (000) disables this function.
CLEAN HEAD COUNTER
Indicates the number of inches (or centimeters) since
a cleaning was last initiated.
RESET COUNTER
Allows the Clean Head Schedule to restart the count,
where:
YES
Resets the CLEAN HEAD COUNTER.
NO
Exits the menu item without changing the current
setting.
CLEAN HEAD NOW
Allows cleaning to begin, where:
YES
Initiates the cleaning process and resets the Clean
Head Counter (see Section 5.5.1).
NO
Exits the menu item without cleaning.