Datamax-oneil DPL Programmer’s Manual Manuel d'utilisateur Page 112

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 296
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 111
Extended System-Level Command Functions
104
STX KtU Read Unique Serial Number from RFID Tag
(Direct Mode – HF [13.56 MHz] ISO15693 Tag Interface)
This command instructs the RFID device to read the unique serial number data from the
tag and then place that data into a replaceable field. It is expected that the tag
transponder will be within the read / write distance of the RFID programming device;
otherwise, “Void” will be printed in the text or bar code label field(s).
This is a sixteen character alphanumeric value; the replaceable field must have an
adequate length.
Syntax:
<
STX>KtU
a
bc
c
<
CR
>
Where:
a
-
The number of retry attempts, 0-9.
b
-
Reserved. Should be 0.
cc
-
Field number in which to place the data (must be 01,
02, 03, etc.) matching the order of Label Formatting
command, U.
A 00 value will send the ID to the host with no printing.
STX KtW Write Data to RFID Tag
(Direct Mode – HF [13.56 MHz] ISO15693 Tag Interface)
This command instructs the RFID device to write data to the tag. It is expected that the
tag transponder will be within the read / write distance of the RFID programming device;
otherwise, a warning will occur and a warning message (Read / Write Fail) will be
displayed.
Syntax:
<
STX>KtW
U
n
1
n
16
B
n
c
n
c
n
c
a
aabcdee…
e
<CR>
Vue de la page 111