Immediate Command Functions
10
SOH A Send ASCII Status String
This command allows the host computer to check the current printer status. The printer
returns a string of eight characters, followed by a carriage return. Each character (see
below) indicates an associated condition, either true (Y) or false (N). Byte 1 is
transmitted first. See <SOH>F.
Syntax:
SOH>
Sample:
<SOH>A
Printer Response:
abcdefgh<CR>
Where:
Possible
Values
Interpretation
Transmit
Sequence
a
-
Y/N
Y
=
Interpreter busy (imaging) 1
b
-
Y/N
Y
=
Paper out or fault 2
c
-
Y/N
Y
=
Ribbon out or fault 3
d
-
Y/N
Y
=
Printing batch 4
e
-
Y/N
Y
=
Busy printing 5
f
-
Y/N
Y
=
Printer paused 6
g
-
Y/N
Y
=
Label presented 7
h
-
Y/N
Y
=
(Internal) Rewinder out or fault 8
SOH a Send ASCII Extended Status String
This command allows the host computer to check an extended current printer status.
The printer returns a string of seventeen characters, followed by a carriage return. Most
characters (see below) indicate an associated condition, either true (Y) or false (N). Byte
1 is transmitted first. See <SOH>F.
Syntax:
<
SOH>a
Sample:
<SOH>a
Printer Response:
abcdefgh:ijklmnop:qrstuvwx<CR>
The printer response size may grow as new requirements are defined. The response will
always be backward compatible and terminated with a <CR>. The user should not
assume a fixed length response.
Vue de la page 17