Extended System-Level Command Functions
59
(CH) Communicated Heat Commands – This command causes the printer to
ignore DPL Heat commands. Ignore by setting value to N. Process by setting value
to Y (default). When set to ignore Heat commands values are controlled via the
menu setting.
(CL) Continuous Label Length See <STX>c for command details.
(CO) Column Offset See Cnnnn for command details.
(CS) Communicated Speed Commands – This command causes the printer to
ignore DPL speed commands. Ignore by setting value to N. Process by setting value
to Y (default). When set to ignore speed values are controlled via the menu setting.
(CT) Communicated TOF Commands – This command causes the printer to
ignore DPL TOF (Gap, Continuous, and Reflective) commands. Ignore by setting
value to N. Process by setting value to Y (default). When set to DPL TOF values are
controlled via the menu setting.