Extended System-Level Command Functions
69
(LW) Label Width – This command sets the maximum limit for the printable width.
Objects extending beyond this limit will NOT print; see Appendix K.
(MCC) Module Command – This command adjusts the size of Flash module on the
optional Expansion Card according to the table below (see Appendix K for
appropriate module details):
Value Module Command Units / Interpretation
Zxx
Where xx =
Size: 1 – 7 Mbytes. This is the amount to be allocated to
Module Z; any remaining memory will be allocated to Module F.
Gxx
Where xx =
Size: 1 – 56, in 128 Kbytes blocks. This is the amount to be
allocated to Module G; any remaining memory will be allocated
to Module X.
(ML) Maximum (Label) LengthSee <STX>M for command details.
(MM) Menu Mode – This command sets the menu access level of the printer –
where User is a basic listing of menu settings and controls.
(MT) Media Type This command selects the printing method: Direct Thermal for
use with heat sensitive media or Thermal Transfer for use with media requiring a
ribbon to create an image.
(MV) Mark ValueThis command sets threshold value for the reflective media
sensor’s “mark” parameter.