Extended System-Level Command Functions
48
<STX>Kc
Parameter Name
Parameter
Pneumonic
Value /
Range
Units /
Interpretation
Command
Equivalent
Legacy Emulation
LE
N, A, P, L
N, A, P, L, M
N = None,
A = Allegro,
P = Prodigy,
L = Prodigy Plus,
M = Prodigy Max
X = XL
N/A
Mark Value
MV
0 – 255 N/A N/A
Maximum Length Ignore
SM
0, 1
0 =
Normal processing,
1 = Ignore
N/A
Maximum Length
ML
0 – 9999 1/100 inch
<STX>M
Media Type
MT
D, T
D = Direct,
T = Thermal Transfer
N/A
Menu Mode
MM
U, A
U = User,
A = Advanced
N/A
Module Command
MCC
Z, G
B
See Command N/A
Network Configuration
(wired and wireless)
NE
No Reprint
NR
Y, N
Y = Enabled,
N = Disabled
N/A